- Applications
- WT-70C is designed for welding of 50kgf/mm² high tensile steel with outstanding mechanical properties.
- Characteristics on Usage
-
- - Typical applications include building, shipbuilding, bridges, machineries, vehicles, offshore structures and general fabrications.
- - It is a metal cored wire for all-position welding with Ar+20~25%CO2 shielding gas.
- Notes on Usage
-
- - Proper preheating(50~150°C) and interpass temperature must be used in order to release diffusible hydrogen which may cause cracking in weld metal when electrodes are used for medium and heavy plates.
- - One-side welding defects such as hot cracking may occur with wrong welding parameter such as high welding speed.
- - Shielding gas should be used Ar+20~25%CO2.
- Sizes Available and Recommended Currents ( DC + )
-
Sizes Available and Recommended Currents ( DC + )
Dia(mmØ) |
1.2 |
1.4 |
1.6 |
Position |
F |
Amp |
180~340A |
200~360A |
200~420A |
HF |
180~340A |
200~360A |
200~420A |
- Typical Chemical Composition of All-Weld-Meta(W%) (Shielding gas : MIX)
-
Typical Chemical Composition of All-Weld-Meta(W%)
C |
Mn |
Si |
P |
S |
0.048 |
1.50 |
0.65 |
0.017 |
0.013 |
- Typical Mechanical Properties of All-Weld-Metal (Shielding gas : MIX)
-
Typical Mechanical Properties of All-Weld-Metal
Y.S MPa |
T.S MPa |
EL(%) |
CVN-Impact Value J (-30℃) |
495 |
550 |
27 |
67 |
- Welding position
- Approved by
- JIS, CWB, CE, ABS, DNV