• Applications
  • WT-111K3 is designed for welding of 760MPa high tensile steel with outstanding mechanical properties.
    Typical applications include high tensile steels that will be used a low temperature environment.
  • Characteristics on Usage
    • - It is a rutile type flux cored wire for all-position welding.
    • - It provides smooth arc, low spatter levels, good weldability and good bead appearance.
    • - It provides excellent impact values at low temperature.
  • Notes on Usage
    • - Proper preheating(50~150℃) and interpass temperature must be used in order to release diffusible hydrogen which may cause cracking in weld metal when electrodes are used for medium and heavy plates.
    • - Gas flow rate is proper 20~25â„“/min.
    • - Shielding gas should be used 100% CO2.
  • Sizes Available and Recommended Currents ( DC + )
  • Sizes Available and Recommended Currents ( DC + )
    Dia(mmØ) 1.2 1.4 1.6
    Position
    F Amp 180~340A 200~360A 200~420A
    HF 180~340A 200~360A 200~420A
    V-up, OH 120~220A 140~260A 160~280A
  • Typical Chemical Composition of All-Weld-Metal (wt%) ( Shielding gas : CO2)
  • Typical Chemical Composition of All-Weld-Metal (wt%)
    C Mn Si P S Ni Mo
    0.04 1.78 0.36 0.011 0.005 2.03 0.36
  • Typical Mechanical Properties of All-Weld-Metal ( Shielding gas : CO2)
  • Typical Mechanical Properties of All-Weld-Metal
    Y.S MPa T.S MPa EL(%) CVN-Impact Value J
    (-20℃)
    767 802 20 114
  • Welding position
  • Welding position
  • Approved by
  • JIS